elightia-logo-red-black-serious-angle-transparent-2k
Request a Quote
Services
Home  ➔  Services
banner02
ENGINEERING SERVICES

Engineering services built around your application

From early feasibility through detailed design and system integration, Elightia provides focused optical, electrical, and electro-optical engineering support.

Discuss Your Project
Engineering services illustration
CAPABILITIES

Specialized Engineering Services

Focused expertise from concept development through detailed design and integration.

Optical Design

Imaging, illumination, and beam delivery systems tailored to your performance goals, from visible and NIR through MWIR and LWIR infrared sensor and imaging design.

Biophotonics

Optical systems for life-science and biomedical instrumentation applications.

Optical Metrology

Precision optical measurement solutions for development and production environments.

Explore Optical Metrology →

PCB Design

High-performance analog, digital, and RF PCB design from concept to fabrication.

Power Electronics

Power conversion and control solutions engineered for reliability and efficiency.

System Integration

Bringing optical, electrical, and mechanical elements together into robust systems.

Simulation, Tolerance & Thermal Analysis

Evaluate performance and trade-offs before hardware, assess sensitivity to manufacturing and alignment, and verify performance across the operating temperature range.

LiDAR & Free-Space Optics

Wide-field transmit and receive optics for LiDAR, laser rangefinding, tracking, and free-space optical communication.

Spectrometer Design

Custom VIS-NIR and NIR spectrometers, from optical layout and detector selection to signal processing, designed for reliable measurement and cost-effective assembly.

INDUSTRIES

Where we work

Application-focused engineering for teams building optical, sensing, and electro-optical products.

Medtech & Biophotonics

Life-science and biomedical instruments, diagnostics, and surgical and ophthalmic imaging optics.

Imaging & Microscopy

Microscope, camera, and machine-vision systems, with ISO-referenced performance testing.

Infrared & Defense

MWIR and LWIR thermal imaging, infrared sensors, and ruggedized electro-optical systems.

LiDAR & Free-Space Optics

Rangefinding, LiDAR, tracking, and optical communication links.

Spectroscopy & Sensing

VIS-NIR and NIR spectrometers for food, agriculture, process, and chemical analysis.

Hardware Startups

Independent optics and electronics support for teams without in-house specialists.

Optical metrology

Understand your optical system’s performance

Elightia provides optical performance characterization, measurement troubleshooting, and test-method development for optical components and integrated systems.

We develop application-specific test configurations, procedures, and reports to support product development and production testing.

Discuss Your Measurement Needs

Optical metrology

Optical performance, from the center to the edge

Evaluate image quality, focus, aberrations, geometry, and illumination across the optical field. We define measurement configurations around the system’s intended wavelengths, aperture, magnification, and operating conditions.

Performance characterization

  • MTF and lateral resolution: characterize contrast transfer and fine-detail reproduction on-axis and at selected off-axis field positions.
  • Focus accuracy and diopter error: evaluate focus settings and optical focus offsets.
  • Aberration characterization: investigate spherical and axial chromatic aberration, coma, astigmatism, and field curvature.
  • Geometric distortion: measure departures from the intended image geometry.
  • Vignetting and relative illumination: evaluate brightness falloff across the field.
On-axis and off-axis resolution targets showing contrast at the center and across the field
Evaluate resolution and contrast at the center and across the optical field.

Methodology alignment
Applicable MTF measurements reference ISO 9335:2025, while distortion measurements reference ISO 9039:2008 within its scope. Operation and stereomicroscope resolution and focus evaluations reference ISO 10936-1:2017 and ISO 15227:2000 where applicable. Other aberration measurements use application-specific procedures.

MTF, sampling, and the diffraction limit

H and V curves compare contrast transfer in two orthogonal spatial-frequency directions. The diffraction-limited curve provides an ideal optical reference for the stated wavelength and f-number. The detector Nyquist frequency is 1/(2p), where p is pixel pitch. We also show 1/dA as an Airy-diameter reference, where dA = 2.44 λN is the diameter to the first dark ring. This optical reference is distinct from the detector sampling limit.

Illustrative H and V optical MTF curves with separate markers for sensor Nyquist at 100 lp/mm and reciprocal Airy diameter at 186 lp/mm
Illustrative example of sensor sampling limitations: The optics transmit detail beyond the detector’s 100 lp/mm Nyquist frequency. A sensor with smaller pixels could capture more of this available optical detail. Optical contrast also influences overall image quality. These curves are illustrative, not measured Elightia results.

Example conditions: 550 nm, f/4, and 5 µm detector pixel pitch. Airy diameter: 5.37 µm. Reciprocal Airy-diameter reference: approximately 186 lp/mm. H/V denote spatial-frequency directions, not sagittal/tangential orientation.

System testing

Performance across configurations and channels

Evaluate the complete optical system across magnification settings, stereo channels, and operating conditions. Each test uses defined configurations and agreed acceptance criteria.

Field of view

Measure the visible or imaged area at specified magnification and working distance.

Parfocality

Assess focus consistency when changing magnification or optical configurations.

Depth of field

Determine the object-space range that meets an agreed sharpness criterion.

Stereo disparity and channel alignment

Evaluate relative image position, angular alignment, and image rotation between left and right channels.

Parcentrality and image centering

Measure image-position shifts when changing magnification or optical configurations.

Low-light sensitivity

Characterize image quality under reduced illumination with defined exposure, gain, and performance criteria.

Color Checker testing

Evaluate color reproduction using a characterized color-patch target under defined illumination, exposure, white-balance, and processing settings. Compare captured patch colors with reference values and report color differences using agreed metrics, such as ΔE.

Methodology alignment
Applicable microscope evaluations reference ISO 10936-1:2017 and ISO 15227:2000. Digital-camera shading, sensitivity, noise, and dynamic-range evaluations reference ISO 17957:2015, ISO 12232:2019, and ISO 15739:2023 where their scope applies. Bright-field microscope image brightness and uniformity can reference ISO 19056-1:2015.

Measurement methodology

Testing aligned with applicable ISO standards

Elightia’s optical metrology methodology aligns with applicable ISO test methods and performance requirements, including ISO 10936-1 and ISO 15227 for operation and stereomicroscope evaluation. Additional standards apply according to the optical system and measurement scope. Each project defines the test conditions, applicable references, and acceptance criteria.

A defined scope for every measurement

We establish the optical configuration, field positions, wavelength or illumination conditions, focus criteria, and evaluation methods before testing. Reports identify the applicable references and document agreed deviations or application-specific methods.

Our support includes test setup and fixture development, written test procedures, measurement troubleshooting, and analysis of optical test data.

Applicable standards and reference scopes
ISO 10936-1:2017

Operation microscopes: requirements and test methods.

ISO 15227:2000

Recommended test methods for stereomicroscopes.

ISO 9335:2025

Optical transfer function measurement principles and procedures.

ISO 9039:2008

Distortion measurement for optical systems within its scope.

ISO 17957:2015

Digital-camera shading measurements.

ISO 12232:2019

Digital still-camera sensitivity ratings and exposure index.

ISO 15739:2023

Digital still-camera noise and dynamic-range measurements.

ISO 19056-1:2015

Image brightness and uniformity in bright-field microscopy.

Discuss your measurement needs

Tell us about your optical system, the performance parameters you need to evaluate, and your testing challenges.

Discuss Your Project
FLEXIBLE ENGAGEMENT

Support for complex technical challenges

Consulting & Technical Review

Expert evaluation and guidance to clarify requirements, assess options, and reduce risk. We analyze your challenges and provide actionable recommendations grounded in engineering experience.

Feasibility & Concept Development

Explore ideas, define architecture, and validate performance to confirm the right path forward. We build models, simulations, and prototypes to de-risk your concept and establish a solid foundation.

Detailed Design & Integration

Complete design, verification, and integration to deliver robust, production-ready systems. We execute with precision—delivering documentation, test, and support for a successful launch.

Ready to discuss your application?

Discuss Your Project